These
cables are designed for direct burial application
and provide excellent transmission performance &
protection to fibre in variety of field environment
|
Tensile force (IEC 60794-1-E1)
During Installation
Permanent |
1.3 x W
0.6 x W |
Bending radius (IEC 60794-1-E1)
Temporary, unloaded
Permanent, during installation |
20 D
25 D |
| Repeated bending (EIA-455-104) |
30 times, with weight of 50 N |
| Torsion resistance (IEC 60794-1-E7)
|
10 cycle with load of 400 N |
| Crush resistance (IEC 60794-1-E3)
|
4000 N (100 x 100 mm) |
| Impact resistance (IEC 60794-1-E4)
|
25 N-m |
| Kink resistance (IEC 60794-1-E10)
|
20 D |
|
Temperature range (IEC 60794-1-F1)
Operation
Storage
Installation
|
-30º to +70ºC
-30º to +70ºC
-20º to +50ºC |
| Water Penetration (IEC 60794-1-F5)
|
Pass |
| Spark Test (IEC 60794-1-F3) |
Pass |
| W = Weight in kg of 1 Km. cable
|
D = Diameter of cable in mm. |
|
| Colour of fibres in tube |
Blue, Orange, Green, Brown, Slate,
White, Red, Black, Yellow, Violet, Rose &
Natural
Last fibre in tube will be Natural |
| Colour of loose tube |
Blue, Orange, Green, Brown, Slate,
White, Red, Black |
| Colour of fillers ( Dummy ) |
Black/Natural |
|
|
|
Upto 24 F
|
Upto 48 F |
| Cable weight (nominal) – Kg/Km |
|
226 |
260 |
| Cable diameter (nominal) – mm |
|
15.7 |
16.9 |
| Standard length – Kms |
|
2, 4 & 6
|
2, 4 & 6
|
|
- Fibre in cable can comply to G651/G652 Series/G655
or as desired. Properties of cabled fibre available
on request.
- The given cable cross section and characteristics
will change as per specification desired by the
customers.
|