These
cables are designed for direct burial & duct application
and provide excellent transmission performance &
protection to fibre in variety of field environment
|
Tensile force (IEC 60794-1-E1)
During installation
Permanent |
1.3 x W
0.6 x W |
Bending radius (IEC 607494-1-E11)
Temporary, unloaded
Permanent, during installation
|
20 D
25 D |
| Repeated bending (EIA-455-104) |
30 times, with weight of 50N |
| Torsion resistance (IEC 60794-1-E7) |
10 cycle with load of 400N |
| Crush resistance (IEC 60794-1-E3)
|
4000 N (100 x 100mm) |
| Impact resistance (IEC 60794-1-E4)
|
25 N-m |
| Kink resistance (IEC 60794-1-E 10)
|
20 D |
|
Temperature range (IEC 60794-1-F1)
Operation
Storage
Installation
|
-30º to +70ºC
-30º to +70ºC
-10º to +50ºC |
| Water Penetration (IEC 60794-1-F5)
|
Pass |
| D = Diameter of cable in mm. |
W = Weight in kg of 1 Km.
Cable |
|
| Colour of fibres in a tube |
Blue, Orange, Green, Brown, Slate,
White, Red, Black, Yellow, Violet, Rose &
Natural
Last fibre in tube will be Natural |
| Colour of Loose Tube |
Blue, Orange, Green, Brown, Slate,
White, Red, Black |
| Colour of filler ( Dummy ) |
Black/Natural |
| Colour of Insulated Copper Wires
|
1st Wire of pair - White
2nd Wire of pair - Blue, Orange, Green. Brown
& Grey |
|
| Cable weight (nominal) - Kg / Km. |
250
|
| Cable diameter (nominal ) - mm |
16.2
|
| Standard length – Kms |
2, 4 & 6
|
|
- Fibre in cable can comply to G651/G652 Series/G655
or as desired. Properties of cabled fibre available
on request.
- The given cable cross section and characteristics
will change as per specification desired by the
customers.
|