These
cables are designed for duct application and offer
termite & insect resistance properties; excellent
transmission performance & protection to fibre in a
variety of field environment
|
|
|
Lightning prone areas
|
|
|
Vicinity of power line |
|
|
Long haul communication systems
|
|
|
Local area networks
|
|
| |
|
Tensile force (IEC 60794-1-E1)
During installation
Permanent |
1.3 x W
0.6 x W |
Bending radius (IEC 607494-1-E11)
Temporary, unloaded
Permanent, during installation |
15 D
20 D |
| Repeated bending (EIA-455-104) |
30 times, with weight of 50N |
| Torsion resistance (IEC
60794-1-E7) |
10 cycle with load of 400N |
| Crush resistance (IEC 60794-1-E3)
|
2000 N (100 x 100mm) |
| Impact resistance (IEC 60794-1-E4)
|
25 N-m |
| Kink resistance (IEC 60794-1-E 10)
|
20 D |
|
Temperature range (IEC 60794-1-F1)
Operation
Storage
Installation
|
-30º to +70ºC
-30º to +70ºC
-10º to +50ºC |
| Water Penetration (IEC 60794-1-F5)
|
Pass |
| W = Weight in kg of 1 Km. Cable |
D = Diameter of cable in mm. |
|
| Colour of fibre in tube |
Blue, Orange, Green, Brown, Slate,
White, Red, Black, Yellow, Violet, Rose &
Natural
Last fibre in a tube will be Natural |
Colour of loose tubes
|
Blue, Orange, Green, Brown, Slate,
White, Red & Black |
| Color of filler ( dummy ) |
Black/Natural |
|
| |
Upto
12 F
|
Upto
24 F
|
Upto
48 F
|
Upto
96 F
|
| Cable weight (nominal) - Kg / Km. |
92
|
104
|
35
|
180
|
| Cable diameter (nominal ) - mm |
10.7
|
11.5 |
13.5
|
14.9
|
| Standard length - Kms |
2, 4 & 6
|
2, 4 & 6
|
2, 4 & 6
|
2, 4 & 6
|
|
- Fibre in cable can comply to G651/G652 Series/G655
or as desired. Properties of cabled fibre available
on request.
- The given cable cross section and characteristics
will change as per specification desired by the
customers.
|