These
cables are designed for aerial installation and can
withstand ice, wind & other harsh field environment.
|
| Span Length |
100 Mtrs |
Sag
During Installation
With 1 Kg per Mtr ice load
With 75 Kms per hr wind load
With Combined wind & ice
load |
1.0 Mtrs.
1.5Mtrs.
1.7Mtrs.
2.0Mtrs. |
Tensile force (IEC 60794-1-E1)
During installation
Permanent |
6 x W
3 x W |
Bending radius (IEC 60794-1-E11)
Temporary, unloaded
Permanent, during installation
|
15D
20D |
| Repeated bending (EIA-455-104) |
30 times, with weight of 50N |
| Torsion resistance (IEC 60794-1-E7) |
10 cycle (+ 180º ) with load of
400N |
| Crush resistance (IEC 60794-1-E3)
|
2000N (100 x 100mm) |
| Impact resistance (IEC 60794-1-E4)
|
25 N-m |
| Kink resistance (IEC 60794-1-E 10)
|
20 D |
|
Temperature range (IEC 60794-1-F1)
Operation
Storage
Installation
|
-40º to +70ºC
-40º to +70ºC
-10º to +50ºC |
| Water Penetration (IEC 60794-1-F5)
|
Pass |
| D = Diameter of cable in mm. |
W = Weight in kg of 1 Km.
Cable |
|
| Colour of fibre in a tube |
Blue, Orange, Green, Brown, Slate,
White, Red, Black, Yellow, Violet, Rose &
Natural
Last fibre in a tube will be Natural |
| Colour of lose tube |
Blue, Orange, Green, Brown, Slate,
White, Red, Black |
| Other elements |
Black/Natual |
|
| |
Upto 12 F
|
24 F
|
48 F
|
| Cable weight (nominal) - Kg / Km. |
175
|
200
|
270
|
| Cable diameter (nominal ) - mm |
15.1
|
16.3
|
18.5
|
| Standard lengths-Kms |
2, 4 & 6
|
2, 4 & 6
|
2, 4 & 6
|
|
- Fibre in cable can comply to G651/G652Series/G655
or as desired. Properties of cabled fibre available
on request.
- The given cable cross section and characteristics
will change as per specification desired by the
customers.
|